Introducing an innovative, revolutionary and patented breakthrough technology pioneered by Synergy Energy Inc.
OPTIMIZER, tomorrow's GREEN technology for today's industry

Until now, the most popular method for mitigating 5th and 7th harmonics using a passive device has been the phase shifting. With this approach, two loads, such as Variable Frequency Drives (VFDs), are to work at the same time and have equal power, so harmonics from one source of nonlinear load is used to cancel the ones from the second source. In reality such a perfect condition is very difficult to achieve and two VFDs hardly ever operate simultaneously, making it nearly impossible to apply the principles of phase shifting theory in real life.

As the result of more than 6 years of extensive theoretical research,  and development of many test laboratory apparatuses and real application prototypes, as an unsurpassed solution for simultaneous mitigation of harmonics and correction of power factor, OPTIMIZER™ is set to revolutionize the industry.

In the most simplistic form, OPTIMIZER™ is a passive device, which easily reduces electrical Current Total Harmonic Distortion (ITHD) from 73% to lower than 3.5% and Voltage Total Harmonic Distortion (VTHD) from 10% to less than 1%, which are much lower than the ones required by IEEE 519. This effect in turn creates a clean electrical power atmosphere for all other equipment in a facility.

OPTIMIZER™ improves the power factor to 99.9%, close proximity of 100%, and thereby eliminating surcharges imposed by a utility company. The most important feature of the OPTIMIZER™ is the way it treats the Cause and not the Symptom of the problem.

In a nutshell, OPTIMIZER™ is a patented product that while cleans the electrical power form 5th, 7th, 11th and 13th harmonics without a need for any phase shifting, virtually eliminates any penalties imposed by local power utilities, which may have resulted from a low power factor.

System Configuration with and without OPTIMIZER
Without OPTIMIZER With OPTIMIZER


Test results at Voltage: 480V, Frequency: 60Hz and Non-linear Load: 12.2HP
Line Current Waveform Normal
Line Current Waveform with OPTIMIZER
Line current waveforms without Optimizer
(THDi=71.2% and Power Factor = 0.794 Lag)
Line current waveforms with Optimizer
(THDi=3.5% and Power Factor = 0.999 Lag)
Test results at Voltage: 480V, Frequency: 60Hz and Non-linear Load: 12.2HP
Line Voltage Waveforms without Optimizer Line Voltage Waveform with OPTIMIZER
Line voltage waveforms without Optimizer
(THDv=4.9%)
Line voltage waveforms with Optimizer
(THDv=0.6%)
Power Factor Comparison

Product Catalogue
To view, download, and print the online PDF version of Synergy Energy Inc. Product Catalogue - 2012 Edition,  Synergy Energy Inc. Technical Catalogue - 2012 Edition and Synergy Energy Inc. Options Catalogue - 2010 Edition, please click on the corresponding images below:



Synergy Energy Inc.
Product Catalogue
2012 Edition
Synergy Energy Inc.
Technical Catalogue
2012 Edition
Synergy Energy Inc.
Options Catalogue
2010 Edition



Home | About Us | News | Products | Innovations | FAQ | Quotation | Resources | Contact Us
©Copyright - Synergy Energy Inc.,  Unit 9 - 3182 Orlando Drive, Mississauga, ON, L4V 1R5, Canada
Best viewed on Microsoft Internet Explorer & Mozilla Firefox